IDIS DC-Series | IR reflection glare

Super Admin
06 May 2026
0 views

Environment:

  • DC-Dxxxx Series 
  • DC-Txxxx Series 
  • DC-Sxxxx Series 
  • DC-Yxxxx Series 

Image of issue:
IR glare.jpg

Procedure:

  1. Log onto the DR Series front panel console or the remote to it from IDIS Center.
  2. Click on the "setup" ICON
    SETUP.jpg
  3. Click on the "Camera" Menu.
    camera .jpg
  4. Click on the "Advanced Setup" sub-menu, then the "DOTs" under the "Video" field for the camera needing adjustment.
    adv 2.jpg
  5. Adjust the "3DNR" to a higher level and Lower "IR Strength". Then click Apply.
    Note: In some cases, the IR may need to be turned off if there is lighting in the background.
    ADV menu.jpg
  6. Confirm Image

    clear image.jpg

 

 

Was this article helpful?

Bu bilgiler sorununuzu çözmeye yardımcı oldu mu?

Still need help?

Uzman ekibimiz size yardımcı olmak için burada.

New Ticket