Issue:
An integrator needs a third party horn/light to trigger when someone with a high temperature is detected.
Resolution:

| Number |
Function |
Description |
| 1 |
RS485 |
Used to connect to an external pan and tilt. Supported protocols are Pelco D and P. |
| 2 |
Alarm Input 2 |
Dry contacts (default is closed). |
| 3 |
Alarm Output 2 |
Contact used to connect to an external horn/warning light. Requires external 12VDC or 24VAC (1A max). For clarification, this is simply an open dry contact closed on an event. |
| 4 |
Alarm Input 1 |
Dry contacts (default is closed). |
| 5 |
Alarm Output 1 |
Contact used to connect to an external horn/warning light. Requires external 12VDC or 24VAC (1A max). For clarification, this is simply an open dry contact closed on an event. |
| 6 |
Audio Input |
Used to connect to an external microphone. 1-volt peak to peak. RCA interface. |
| 7 |
Audio Output |
Used to connect to external audio devices. 0.875-volt peak to peak. RCA interface. |
| 8 |
Power Input |
Used to connect to the 12VDC power supply. |
| 9 |
Network Interface |
Used to connect to the customer network. |