An integrator needs a third party horn/light to trigger when someone with a high temperature is detected.

Resolution:

 20200518_995.png

 

Number Function Description
1 RS485 Used to connect to an external pan and tilt. Supported protocols are Pelco D and P.
2 Alarm Input 2 Dry contacts (default is closed).
3 Alarm Output 2 Contact used to connect to an external horn/warning light. Requires external 12VDC or 24VAC (1A max). For clarification, this is simply an open dry contact closed on an event.
4 Alarm Input 1 Dry contacts (default is closed).
5 Alarm Output 1 Contact used to connect to an external horn/warning light. Requires external 12VDC or 24VAC (1A max). For clarification, this is simply an open dry contact closed on an event.
6 Audio Input Used to connect to an external microphone. 1-volt peak to peak. RCA interface.
7 Audio Output Used to connect to external audio devices. 0.875-volt peak to peak. RCA interface.
8 Power Input Used to connect to the 12VDC power supply.
9 Network Interface Used to connect to the customer network.