PREVIOUS STEP: SET STATIC IP ON BOARD AND MONITOR
Access the web component of each of the units by typing their IP addresses in a browser, and click on the "Network --> Basic" tab to configure a static IP.
BOARD

MONITOR

BOARD CONFIGURATION
1) SET IP OF THE MONITOR TO CALL
In the tab "Intercom --> Basic" you must indicate the IP address of the monitor to be called by the board.

2) ENABLE THE RELAY OPENING BY HTTP
In the "Access Control --> Relay" tab, activate the "Open Relay Via HTTP" option and specify a User Name and Password, which will be used in the subsequent configuration of the relays for the monitor (they can be different from the credentials of the equipment).

MONITOR CONFIGURATION
1) ADD THE BOARD AS A CAMERA
In the "Phone --> Monitor" tab, the camera of the external board must be added, indicating the following parameters:
a) Device Number: MAC of the board.
b) Device Name: name of the board (you can choose the one you prefer).
c) RTSP Address: RTSP address of the board (rtsp://IP_PLACA/live/ch00_0)
d) User Name/Password: user and password to access the board (by default admin/admin).
e) Display In Call: it is marked as Disabled.

2) ENABLING THE DISPLAY OF THE BOARD DURING CALLS
In the "Phone --> Intercom" tab, check the "Intercom Preview" box as Enabled.

3) SET RELAY OPENING
On the "Phone --> Relay" page, "Remote Relay HTTP" should be specified in the Softkey In Talking Page, Softkey In Monitor Page and Softkey In Call-Preview Page sections.

Then, in "Remote Relay By HTTP", the data corresponding to the board must be entered, indicating:
a) IP/SIP: IP address of the board.
b) User Name/Password: user and password indicated in the Open Relay Via HTTP step of the panel.
c) Door Number: number of the relay to be affected.

NOTE: in some models of monitors the URL field is also indicated, where it must be entered:
FW without High Security Mode:
http://IP_PLACA/fcgi/do?action=OpenDoor&UserName=USER_PLACA&Password=PASSWORD_PLACA&DoorNum=NUM_RELE
FW with High Security Mode:
http://USER_PLACA:PASSWORD_PLACA@IP_PLACA/fcgi/OpenDoor?action=OpenDoor&DoorNum=NUM_RELE
4) ADD THE BOARD AS A CONTACT
Finally, in the "Contacts --> Local Contacts" tab, the contact related to the plate must be created:
a) Name: name of the board (recommended to give it the same name you gave to your camera in the Monitor step).
b) Number 1: IP address of the board.