DT-R00x Relay Module configuration with Uniview NVR

Super Admin
07 May 2026
11 views

In the Uniview recorders of the B-IQ ranges, compatibility with DT-R00x relay modules has been added.

The recorders support a maximum of 8 DT-Rxxx modules, with no limitation of Inputs/Outputs

Once the module and recorder are configured in the same network, it is only necessary to add the IP of the module in the NVR from the Alarm Extension section:

  • Module IP
  • Module communication port - 502
  • Number of module inputs
  • Number of module outputs

Once added in the NVR you can start configuring both inputs and outputs in the same way as the physical inputs and outputs of the recorder itself or the IP cameras


IMPORTANT: There is an important configuration to be done in the relay module, which is to disable the default operation of the terminal

  • The first step will be to deactivate the Input Contorl Relay option, since this option is for each input of the module to activate its output, input 1 activates output 1, input 2 activates output 2,...